ASTM E605 PDF

SPRAY FIREPROOFlNG—ASTM STANDARDS. ASTME E — Standard Test Methods for Thickness and Density of Sprayed Fire-Resistive Material. ASTM-Epdf – Download as PDF File .pdf), Text File .txt) or read online. Description: Standard Test Methods for Thickness and Density of Sprayed Fire- Resistive Material (SFRM) Applied to Structural Members. View More. Standard.

Author: Vogul Brabei
Country: India
Language: English (Spanish)
Genre: Automotive
Published (Last): 24 February 2016
Pages: 282
PDF File Size: 8.99 Mb
ePub File Size: 2.84 Mb
ISBN: 853-7-90049-958-3
Downloads: 11650
Price: Free* [*Free Regsitration Required]
Uploader: Akimuro

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. Thickness measurements are concerned with the astm e605 of the SFRM, while the density measurements pertain to the product itself.

Testing Engineers – Case Studies

Link to Active This link will always route to the s605 Active version of the standard. It makes astm e605 reference to Note 4 in using a correction formula.

It is the intent of these test methods to provide procedures to determine these properties. Combining values from the two systems may result in non-conformance with the standard. For every sq. Work Astm e605 s – proposed revisions ashm this standard. Historical Version s – view previous versions of astm e605.

This would result in an overstatement of the protection level, which must be avoided. Is this a contradiction and which frequency should e65 used? It is the astm e605 of the user of this standard to establish appropriate safety astm e605 health practices and determine the applicability of regulatory limitations prior to use. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other.

The IBC uses E for thickness astm e605 but has wording that supersedes E on the ast, of testing.

It reduces some of the measuring and sampling variables that are inherent with other methods. And Note 4 states the following: Active astm e605 current version of standard. Link to Active This link will always route astm e605 the current Active version of the standard. My question is after xstm the cap with epoxy and letting it set for approximately 24 hours are we to cut around the astm e605 to the substrate or are we to test it in-place without cutting around the cap?

Most 10 Related  IEC 61558-1 PDF DOWNLOAD

So, astm e605 writing an SOP for performing thickness determination the following could be adopted: This standard does not purport to address all of the safety concerns, if any, associated with its use.

E conducts thickness testing at a Rate of one bay per floor or one bay for each 10, sq.

As a laboratory we believe the measurements should be actual not allowables. The values given in parentheses are for information only. ICS Number Code Referenced Documents purchase axtm The astm e605 listed below are referenced within the subject standard but astm e605 not provided as part of the standard. When measuring density, IBC refers us to section 8.

These include sprayed fiber and cementitious astm e605. Consult the rating criteria. For SFRM to provide the required level of protection both the minimum average thickness and the density requirements must be met. Astm e605 Item s – proposed revisions of this standard.

The apparatus, materials, and procedure used to apply the SFRM for laboratory tests shall be the same as is used astm e605 the construction of either of the test assemblies described in Test Methods E and E While the wording in asfm manual seemed confusing, an appendix clarified that astm e605 thickness measurements astm e605 be taken. The test methods are applicable to both laboratory and field procedures, as indicated in Section.

If the density of the SFRM does not meet the design criteria can an increase of thickness compensate for the deficient density?

Standard: ASTM E605

E conducts thickness testing at a rate of one astm e605 per floor or one bay for each 10, sq. It can be used to retest a sample that may be in question. ICS Number Code It is astm e605 responsibility of the user of ast, standard to e6605 appropriate safety and health practices and determine the astm e605 of regulatory limitations prior to use.

Most 10 Related  LEONE FROLLO EPUB DOWNLOAD

With such a ast discrepancy between the two can you explain the right procedure? This change has drastically increased the amount of testing on fluted decks. It would be appropriate to mention the alternate method for determining the in-place density stated, in ASTM E Section 8. If we go back to the IBC From a practical viewpoint, the use of actual measurements for density calculations astm e605 “false high” density calculations.

The apparatus, astm e605, and procedure used to apply the SFRM for laboratory tests astm e605 be the same as is used for the construction of either of the test assemblies described in Test Methods E and E The concept of a correction formula has a valid basis and should not be astm e605 f605 a loop hole or an easy way out. It is based on the same design concept of the original tested assembly but it is up to the design professional to determine if the increase aatm thickness compensates for the low density of the SFRM.

astm e605 The test methods are applicable to both laboratory and field procedures, as indicated in Section 7. During a recent project we found the Sprayed Astm e605 Material applied to the steel substrate to sound hollow upon surface tapping.

Bond Strength of Fireproofing. Also I e65 encourage you and your team to use the displacement method for determining density, Section 8. A sample Operating Procedure follows: He stated the following: